Quantcast
Channel: Reprap Forum - Firmware - Marlin
Browsing all 2831 articles
Browse latest View live
↧

G29 Auto bed leveling extreme squish (2 replies)

With a newly installed z induction probe, I can use auto-bed leveling (ABL), yay! BUT, I have an extreme case of z-layer squish because of it. In the first 10mm wihere ABL is compensating, my 10mm...

View Article


Z Safe Homing - is this the expected behavior? (1 reply)

I have just upgraded from 1.1.9 to 2.0.7.2. And as part of that, enabled Z Safe Homing. This is what happens: when I do a G28, the X and Y are homing (X0, Y0). Then the probe is moving to the middle...

View Article


#define DEFAULT_LEVELING_FADE_HEIGHT 3 (2 replies)

Hi, I am wanting to set a default value for probe z fade height when I compile Marlin if possible rather than using M420 commands in my slicer's start gcode. I am wondering if I am using Marlin 1.1.9...

View Article

Use StallGuard for Z_MAX endstop (no replies)

Hi, is it possible to define a StallGuard function in Marlin for Z_MAX position detection instead of Endstop sensor? HW: I connected the ZDIAG pin of the TMC 2209 driver with the Z-MAX pin, but it...

View Article

Does marlin have a function to do this? (1 reply)

Hi all, don't know if this is a crazy question or not. If I had a pulley on a sliding plate driven by a stationary stepper "x" and belt looped around the pulley. Slide is pulled back and forth with...

View Article


Marlin-2.0.x (1 reply)

Guten Tag, ich möchte die funktionierende Firmware Marlin-1.1.x durch Marlin-2.0.x ersetzen und habe dazu die Angaben zu Schrittmotoren und Hotend in Configuration.h und Configuration_adv.h...

View Article

Z axis Home and First print layer confusion (no replies)

After the burnout of the original Eaglemoss Mother and Daughter boards I determined to rebuild the Vector 3 printer using: Raspberry Pi, Arduino Mega 2560 and Marlin 2.x firmware. But I am stuck with...

View Article

Electromagnetic Switching Toolhead (no replies)

I'm trying to configure "electromagnetic switching toolhead" for my costum 3D Printer construction. My Printer is running on the SKR PRO v1.1 + TMC2209 + Marlin Firmware 2.0.7.2. I have 3 tools that...

View Article


Need help connecting an arduino tft to a SKR Pro (1 reply)

I am trying to setup an SKR Pro V1.2 with this Arduino TFT (ILI9486) [www.amazon.ca] But I do not know how to connect it up and then how to configure it in Marlin. I have tested the screen on an...

View Article


Marlin Pause at Sensor or Change in Pinstate (no replies)

Dear All , I need your help... I am working on a project that require following sequence of activities: 1- DC motor is installed with a index sensor on its wheel 2- We have an XY table that moves with...

View Article

Negative Nozzle to probe offzet on Z not working (no replies)

Hi, I've just updated the printer to the last firmware, after re-applying my settings and calibrating my inductive probe my Z height is off. I've re calibrated the Z height but without any luck. In...

View Article

What are these Marlin terms? (no replies)

Running Marlin 2.0.7.2 on an Anycubic Predator delta. After running "Auto Delta Calibration" from the LCD, I get: Height: 453.00 Ex: 0.000 Ey: -4.969 Ez: -4.960 Radius: 216.69 Tx: 0.485 Ty: -0.352 Tz:...

View Article

Markforged XZ kinetics information (no replies)

I found out in another post the name of Markforged XY kinetics and now looking for some more information on it. I see in the latest release marlin has the markforged xy now included. Does anyone know...

View Article


Axis not stopping when homing and triggering bltouch (no replies)

Hello, pretty new user to this forum and hope i'm following all the rules :-) I have a creality cr-10s pro v2. Everything was working as expected up to the point whern i decided i needed a e3d titan...

View Article

Marlin Auto Calibration (no replies)

I'm running a Trigorilla Pro board under Marlin 2.0.7.2 on an Anycubic Predator delta. I've changed the original microswitch z probe to a nozzle contact piezo sensor, and all is well BUT: When I do an...

View Article


Endscript not working with latest Marlin 2.0.7.2 bugfix (no replies)

I used the latest Marlin 2.0.7.2 bugfix from 18 feb 2021 and can not run my endscript any more.I think there is a define mode M84 in the software that I must undefine. M84 is now incorporated in the...

View Article

X - axis is not homing but moves correctly (no replies)

Hi, I have paused my work on a Hypercube and modified something on the Marlin firmware. The problem now is when I home the X-axis the axis just moves about 1cm in the wrong direction and then it...

View Article


Bed leveling API for THC (no replies)

I am thinking of using bed leveling as THC for a plasma CNC. My idea is to fake the bed leveling calibration and then use the bed leveling API when moving across the "bed". Instead of returning a...

View Article

Quick Return to Info Screen? (2 replies)

So, you're buried deep in the Marlin sub-menus and want to get back to the top-level Info Screen. Scroll-up, click on the top entry to go back one menu Scroll-up, click on the top entry to go back one...

View Article

Reorganize menu items in Marlin 2.0.x (1 reply)

Does anyone know how to move an menu item in the menu "print from TF" from bottom to the top position? Now I have this item on the 6. position and I must scroll and scroll down. MARLIN 2.0.x on the...

View Article
Browsing all 2831 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>